AWWA C905-10: PVC Pipe for Sewer Applications - North American ...
AWWA C905-10: PVC Pipe for Sewer Applications - North American ...
AWWA C905-10: PVC Pipe for Sewer Applications - North American ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>AWWA</strong> <strong>C905</strong>-<strong>10</strong>: <strong>PVC</strong> <strong>Pipe</strong> <strong>for</strong> <strong>Sewer</strong> <strong>Applications</strong><br />
<strong>North</strong> <strong>American</strong> <strong>Pipe</strong>'s <strong>AWWA</strong> <strong>C905</strong>-<strong>10</strong> <strong>PVC</strong> product line<br />
is manufactured to meet the needs of modern<br />
reclaimed water distribution systems. With top quality<br />
raw materials and modern processing technology <strong>North</strong><br />
<strong>American</strong> <strong>Pipe</strong>'s <strong>C905</strong>-<strong>10</strong> reclaimed water pipe meets<br />
all industry standards in addition to our own rigorous<br />
quality control standards. <strong>North</strong> <strong>American</strong> <strong>Pipe</strong>’s <strong>C905</strong>-<br />
<strong>10</strong> pipe utilizes Reiber style gaskets throughout the<br />
entire product offering. <strong>North</strong> <strong>American</strong> <strong>Pipe</strong> produces<br />
a broad range of CIOD pipe in DR-14, DR-18, DR-21, DR-<br />
25, DR-32.5, DR-41 and DR-51 classifications. Whether<br />
specifying or installing our pipe you can be assured that<br />
<strong>North</strong> <strong>American</strong> <strong>Pipe</strong> will provide the pipe “Right, On<br />
Time, All the Time”.<br />
<strong>Pipe</strong> Standard: <strong>AWWA</strong> <strong>C905</strong>-<strong>10</strong><br />
<strong>Pipe</strong> Compound: ASTM D1784 Cell Class 12454<br />
Gasket: ASTM F477<br />
Integral Bell Joint: ASTM D3139<br />
<strong>Applications</strong>: <strong>Sewer</strong><br />
Color: Green<br />
Lay Length: 20’<br />
Installation: <strong>North</strong> <strong>American</strong> <strong>Pipe</strong>’s<br />
Installation Guide <strong>for</strong> <strong>PVC</strong><br />
Pressure <strong>Pipe</strong><br />
Note:<br />
Short Form Specification<br />
<strong>AWWA</strong> <strong>C905</strong>-<strong>10</strong>, <strong>Sewer</strong> <strong>Applications</strong><br />
<strong>AWWA</strong> <strong>C905</strong>-<strong>10</strong> pipe <strong>for</strong> sewer applications is<br />
made to the same specifications as <strong>AWWA</strong><br />
<strong>C905</strong>-<strong>10</strong> pipe <strong>for</strong> water applications but is not<br />
UL or NSF approved.
<strong>AWWA</strong> <strong>C905</strong>-<strong>10</strong>: <strong>PVC</strong> <strong>Pipe</strong> <strong>for</strong> <strong>Sewer</strong> <strong>Applications</strong><br />
NOMINAL<br />
PIPE SIZE<br />
OUTSIDE<br />
DIA. – NOM.<br />
(OD)<br />
*APPROX.<br />
BELL DIA.<br />
(BD)<br />
**APPROX.<br />
BELL DEPTH<br />
(C)<br />
INSERT<br />
MARK<br />
(L)<br />
14” 15.3 18.75 9.00 8.00<br />
16” 17.4 21.00 <strong>10</strong>.00 9.00<br />
18” 19.5 23.50 <strong>10</strong>.38 9.38<br />
20” 21.6 26.25 11.00 <strong>10</strong>.00<br />
24” 25.8 31.25 13.00 12.00<br />
30” 32.0 37.25 15.13 14.13<br />
36” 38.3 43.30 19.13 18.13<br />
NOMINAL PIPE<br />
SIZE<br />
PR 80<br />
DR 51<br />
(T)<br />
PR <strong>10</strong>0<br />
DR 41<br />
(T)<br />
PR 125<br />
DR 32.5<br />
(T)<br />
PR 165<br />
DR 25<br />
(T)<br />
PR 200<br />
DR 21<br />
(T)<br />
PR 235<br />
DR 18<br />
(T)<br />
PR 305<br />
DR 14<br />
(T)<br />
14” .612 .729 .850 1.093<br />
16” .424 .535 .696 .829 .967 1.143<br />
18” .476 .780 .929 1.083<br />
20” .527 .864 1.029 1.200<br />
24” .629 .794 1.032 1.229 1.433<br />
30” .627 .780 .985 1.280 1.524<br />
36” .751 .934 1.178 1.532 1.824<br />
Note: These dimensions are <strong>for</strong> estimating purposes only * Dimension given <strong>for</strong> Approx. Bell Diameter (BD) is <strong>for</strong> highest pressure class<br />
** Nominal depth, depth will vary by pressure class